惠普/HPLJ1000激光打印机不进纸故障及维修方式
故障现象:惠普/HPLJ1000激光打印机不进纸
检测与分析上诉现象产生问题可能有有一下几点:
1)打印机卡纸的时候 纸张向进纸辊方向拉出 纸槽里面有一块黑色的塑料就会倾斜下来 也会导致打印机不进纸
2)打印机长时间使用机器的搓纸轮老化 也会导致打印机不进纸
3)打印机进纸杆的一侧连接着一个离合齿轮 离合齿轮内侧有一个小的弹簧 打印机卡纸只要向会拉 离合齿轮的弹簧就会蹦出来 造成不进纸
检修结果:该机经上述对症处理后,故障排除。
惠普/HPLJ1000激光打印机连续进纸故障及维修方式
故障现象:惠普/HPLJ1000激光打印机连续进纸
检测与分析:打印机在打印文档的时候 第一纸进去以后 搓纸轮走完一个周期以后 第二张纸又跟着上去了 拆开打印机检测了一下进纸部位传感器 也在正常位置 接着打开进纸组件这块 发现 离合器下方的一个吸垫器始终保持的是贴合的状态 仔细发现吸垫器的黑色泡棉由于长时间贴合的压力 泡棉已经老化了 造成离合齿轮不能正常的分离 机器也就连续进纸,故障解除。The printer when printing a document after the first paper in paper rubbing wheel go through a cycle after the second piece of paper and follow up open printer detection the feed position sensor is in the normal position and then open the feedcomponents found a suction pad clutch beneath the remains is attached to statecarefully found suction pad black foam due to pressure foam long time joint has been aged the clutch gear can not machine normal separation is continuous feed,trouble removal.
惠普/HPLJ1000激光打印机纸张未出完卡纸故障及维修方式
故障现象:惠普/HPLJ1000激光打印机纸张未出完卡纸
检测与分析:打印机在打印过程中 纸张还有三分之一没有出来 拆开打印机加热组件那块1)定影膜是靠硅脂油滚动的更加顺畅 如果缺少硅脂油 机器也会在加热部位纸张出不完 2)加热膜下方的压力辊长时间转动 已经处于老化阶段 出纸时上下之间不够精密也会 造成纸张出不来 3)压力辊下方左右各有两个塑料的轴套 长期磨损 造成压力辊和加热膜之间的间隙增大 也会纸张出不来 4)固定定影上棍铁片左右两侧各有两个弹簧 长期处于拉着的状态 在机器长时间不停的转动情况下 也会造成变形 使得打印纸张未出完卡纸。该机经上述对症处理后,故障排除。The printer in the print paper and 1/3 not out open the printer heating componentthat block 1) fuser film is rolling on silicone oil more smoothly if the lack of siliconeoil machine also will not be finished in the heating position paper 2) pressure rollerlong time heating membrane below the rotation is in between the ageing stagewhen a paper is not enough precision can also cause the paper not to 3) pressurerollers around each sleeve two plastic long-term wear caused by the gap between the pressure roller and the heating film increases will also paper not 4) fixed on the fixing rod of iron on both sides with two springs in the long-term holding state iskept in the the machine long time can also cause deformation of the print paper,not out of cardboard. The machine is the symptomatic treatment, troubleshooting.